Neve 8026 mk I and mk II
8026 | 16/8/16 SPLIT
MONITOR A#613 MAY 1973 TO AUG 1974 |
inputs | 16x
1073 channel amp 16x 1943 aux/group switch router 16x P&G 11-1500 series fader |
post-fade o/p | BA283AM/LO1166 |
group outputs | 8x groups
w panL/R,direct 8x 3402 amplifiers 8x 1943 aux/group switch router (reroute) 8x P&G 11-1500 series fader |
aux/cue sends | 8 aux sends - 4 pots fdg pairs ea sw pre/post |
mon/remix rtns | 16 on single panel feeds to 4T remix + 2aux |
reverb returns | 4x 1900
switcher feeds 8 grps + 6 sends 4x correction units can easily be 1073's 4x P&G 11-1500 series fader |
correction units | 2x 2254/A
comp/lim 4x 2065 HP/LP filter or plug compatible |
other | xxx |
other | xxx |
docs | EB10363 EC10336 |
comment |
1943module changed layout in March 1975 - which may coincide with change to Mk II ? - conflict in docs regarding input count 16 or 24 >>> 8026 24 Input
8 Bus 16 Track Music Recording Console |
8026 Mk II | 16or24/8/16 SPLIT
MONITOR FEB 1974 and after |
inputs | channels
1-24 the same... 1073 channel amp 1943 aux/group switch router channel fader |
post-fade o/p | BA283AM/LO1166 |
group outputs | Groups
1-8 the same... 3405 group amp 1943 group switching unit group fader |
aux/cue sends | 8 aux sends on 4 pots feeding pairs each pair sw pre/post fader |
mon/remix rtns | 16 on single panel feeds to 4 of the 8 aux send busses and 4T buss |
reverb returns | echo
rtns 1-4 the sane 1901 switcher feeds 8 groups |
other | 4x 2254/A
comp/lim 2065 HP/LP filter |
other | xxx |
other | xxx |
docs | EB10363 EC10336 |
comment |
1943 in this console is has auxes laid out differently after March 1975 - conflict in docs regarding input count 16 or 24 >>> 8026 24 Input 8
Bus 16 Track Music Recording Console |